Conference Proceedings Detail Page

From a Low Cost Spectrograph to a High Resolution Spectrograph
written by Timothy T. Grove
We have been using low-cost spectrographs called shoebox spectrographs for a few years. In the process of our study, we decided to make a spectrograph using the same basic optical design but with quality optical parts. This new spectrograph was found to be easily aligned, very accurate (~ 0.2 Angstrom accuracy), and enables intermediate and advanced students to study molecular spectral lines. We will present theory of operation as well as accurate photographs of molecular spectra.
2015 Conference on Laboratory Instruction Beyond the First Year of College
Part of the BFY Conference series
College Park, MD: July 22-24, 2015
Pages 32-35
Subjects Levels Resource Types
Education Practices
- Curriculum Development
= Laboratory
General Physics
- Equipment
Modern Physics
- Atomic Physics
= Spectra
Optics
- Diffraction
- Upper Undergraduate
- Instructional Material
= Laboratory
- Reference Material
= Article
Material Category Formats Ratings
- Articles and Supplements
- application/pdf
  • Currently 0.0/5

Want to rate this material?
Login here!


Format:
application/pdf
Mirror:
https://doi.org/10.1119/bfy.2015.…
Access Rights:
Free access
License:
This material is released under a Creative Commons Attribution 3.0 license. Further distribution of this work must maintain attribution to the published article's author(s), title, proceedings citation, and DOI.
Rights Holder:
American Association of Physics Teachers
DOI:
10.1119/bfy.2015.pr.008
PACSs:
07.57.-c
07.60.Rd
Keywords:
Advanced Lab, BFY 2015, Spectra, Spectrograph
Record Cloner:
Metadata instance created November 17, 2015 by Lyle Barbato
Record Updated:
November 19, 2015 by Bruce Mason
Last Update
when Cataloged:
November 17, 2015
ComPADRE is beta testing Citation Styles!

Record Link
AIP Format
T. Grove, , presented at the 2015 Conference on Laboratory Instruction Beyond the First Year of College, College Park, MD, 2015, WWW Document, (https://www.compadre.org/Repository/document/ServeFile.cfm?ID=13800&DocID=4220).
AJP/PRST-PER
T. Grove, From a Low Cost Spectrograph to a High Resolution Spectrograph, presented at the 2015 Conference on Laboratory Instruction Beyond the First Year of College, College Park, MD, 2015, <https://www.compadre.org/Repository/document/ServeFile.cfm?ID=13800&DocID=4220>.
APA Format
Grove, T. (2015, July 22-24). From a Low Cost Spectrograph to a High Resolution Spectrograph. Paper presented at 2015 Conference on Laboratory Instruction Beyond the First Year of College, College Park, MD. Retrieved December 12, 2024, from https://www.compadre.org/Repository/document/ServeFile.cfm?ID=13800&DocID=4220
Chicago Format
Grove, Timothy. "From a Low Cost Spectrograph to a High Resolution Spectrograph." Paper presented at the 2015 Conference on Laboratory Instruction Beyond the First Year of College, College Park, MD, July 22-24, 2015. https://www.compadre.org/Repository/document/ServeFile.cfm?ID=13800&DocID=4220 (accessed 12 December 2024).
MLA Format
Grove, Timothy. "From a Low Cost Spectrograph to a High Resolution Spectrograph." 2015 Conference on Laboratory Instruction Beyond the First Year of College. College Park, MD: 2015. 32-35 of BFY Conference. 12 Dec. 2024 <https://www.compadre.org/Repository/document/ServeFile.cfm?ID=13800&DocID=4220>.
BibTeX Export Format
@inproceedings{ Author = "Timothy Grove", Title = {From a Low Cost Spectrograph to a High Resolution Spectrograph}, BookTitle = {2015 Conference on Laboratory Instruction Beyond the First Year of College}, Pages = {32-35}, Address = {College Park, MD}, Series = {BFY Conference}, Month = {July 22-24}, Year = {2015} }
Refer Export Format

%A Timothy Grove %T From a Low Cost Spectrograph to a High Resolution Spectrograph %S BFY Conference %D July 22-24 2015 %P 32-35 %C College Park, MD %U https://www.compadre.org/Repository/document/ServeFile.cfm?ID=13800&DocID=4220 %O 2015 Conference on Laboratory Instruction Beyond the First Year of College %O July 22-24 %O application/pdf

EndNote Export Format

%0 Conference Proceedings %A Grove, Timothy %D July 22-24 2015 %T From a Low Cost Spectrograph to a High Resolution Spectrograph %B 2015 Conference on Laboratory Instruction Beyond the First Year of College %C College Park, MD %P 32-35 %S BFY Conference %8 July 22-24 %U https://www.compadre.org/Repository/document/ServeFile.cfm?ID=13800&DocID=4220


Disclaimer: ComPADRE offers citation styles as a guide only. We cannot offer interpretations about citations as this is an automated procedure. Please refer to the style manuals in the Citation Source Information area for clarifications.

Citation Source Information

The AIP Style presented is based on information from the AIP Style Manual.

The APA Style presented is based on information from APA Style.org: Electronic References.

The Chicago Style presented is based on information from Examples of Chicago-Style Documentation.

The MLA Style presented is based on information from the MLA FAQ.

From a Low Cost Spectrograph to a High Resolution Spectrograph:


Know of another related resource? Login to relate this resource to it.
Save to my folders

Contribute

Related Materials

Similar Materials